The importance of supervised monitoring modules used in control and monitoring of extinguishing systems

In many places from chemistry laboratories to industrial amenities, to be able to guarantee the protection of life and property towards a possible hearth hazard, extinguishing systems are used along with detection and alarm techniques. It can be extremely important that the extinguishing techniques installed could be triggered by the fireplace extinguishing management panel, in order to get rid of a attainable fire with early intervention.
In เกจวัดแรงดันแก๊ส to satisfy these wants, and with 35 years of sectoral knowledge and experience, Mavili Elektronik provides:
Maxlogic Conventional Fire Extinguishing Control Panel operating in accordance with the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which allows the remote efficiency of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which permits the extinguishing process to be began manually and remotely; and
to ensure that the extinguishing process can be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these units are produced using surface-mount know-how and are geared toward making the automation of the extinguishing system and hearth and gasoline detection system good.
Image copyright: Mavili
Mavili Elektronik develops its merchandise by all the time considering the needs of the set up. In instances that require the combination of the extinguishing system with the clever addressable fire detection system, it provides options via the monitoring modules that also have a ‘supervised’ choice.
Supervised monitoring modules play an necessary role in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a possible open or brief circuit within the wiring between the contact monitoring modules and the peripheral methods could cause disruption of the triggering, with doubtlessly crucial consequences. For this reason, when selecting monitoring modules, it ought to be taken into account that they have supervised features.
Image copyright: Mavili
Since Maxlogic intelligent addressable fireplace detection and alarm management panels are continuously speaking with ‘supervise’ contact monitoring modules connected to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it easier to watch conditions corresponding to open circuits and short circuits which will occur within the system. Many duties could be carried out within the hearth extinguishing installation, such because the control and monitoring of all valves that can interrupt the flow of water, water flow alarm switches, stress switch, and electric or diesel hearth pumps.
By adding two contact monitoring modules to two separate relay outputs located above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be used to control errors and the other to regulate the fire situation, monitoring and management of the extinguishing system through an clever addressable hearth detection and alarm system may be performed effectively.
For more info, go to www.mavili.com.tr/en