On-site calibration of measuring instruments is often very time-consuming and expensive. This is especially true for applications with several measurands. Perspective of this is the metering skid, something for the custody transfer measurement of the amount of natural gas transferred. Never in the industry from Saudi Arabia has significantly streamlined the testing process at this stage: with the multi-functional CPH8000-P1 calibrator from WIKA, a ?calibration laboratory in an incident?.
The heart of a metering skid is the flow computer. It processes the info from all the measuring instruments and calculates the exact amount of natural gas that flows to the customer. Natural gas is compressible, so the tabs on pressure and temperature during gas transfer plays a crucial role.
Verification is the law
Because even small measuring errors can cause noticeable losses in turnover, the measuring instruments must be calibrated regularly. Normally, this is done at the facility. Each on-site calibration must be verified relative to regulations. This means proving consistent repeatability of the test outcomes and traceability to the assigned references. Furthermore, the regulations require the test equipment to be approved for used in hazardous areas.
In view of the requirements, the calibration personnel of WIKA customers previously had to utilize many different devices so that you can adequately fulfil their tasks. Besides pressure and temperature calibrators, this included a pneumatic pump for the test pressure, a HART� communicator and a resistance decoder. The on-site calibration cost effort and time accordingly.
The CPH8000-P1 multi-functional calibrator significantly reduces the effort necessary for on-site calibration.
Four measuring channels
The natural gas company in Saudi Arabia has reduced this effort in a single fell swoop with the CPH8000-P1 portable multi-function calibrator from WIKA. The case-mounted instrument calibrates pressure measuring instruments together with resistance thermometers and thermocouples. The test pressure is generated having an integrated pump. The CPH8000-P1 has four measuring channels. It can thus perform and display around four measurements simultaneously. The ATEX-approved version also supplies the test items and reference sensors in the metering skid with voltage (DC 24 V) without danger.
Documentation without problems
Through the test procedure, the CPH8000-P1 ? via its integrated HART� module ? communicates directly with the measuring instruments, which are also HART�-capable. Its powerful data logger and the large memory capacity support the user in the next documentation of the on-site calibration. The machine provides all the information relevant for verification.
Note
Detailed info on the model CPH8000 multi-function calibrators can be acquired on the WIKA website. Each instrument includes a modular design and can therefore be specified for the respective selection of applications. In case you have any further questions, your contact will gladly assist you to.

Leave a Reply